К содержанию
РецензированоEN2021

THE RESEARCH OF CURRENT DIFFERENCE MEASURE ERRORS OF NEW INDUCTION CONVERTER

S.F. Amirov · S.X. Jumaboev (Tashkent state university of transport, Address: 1 Temiryoʻlchilalar str., 100167 Tashkent city, Republic of)

American Journal Of Applied Science And Technology · 02 · 631-649 · 2021

Аннотация

The article examines the large inductance difference passing through adjacent busbars and the new induction converter errors designed to measure the symmetry of three-phase currents using the parametric structure method. The additive components of the error are shown in the variable parametric structure diagram as a correction to the output size, and the multiplicative components - in the form of a transmission coefficient or correction to the parameter. It has been found that the input of errors in the form of corrections to the inter-chain transmission coefficients, magnitudes and parameters in the parametric structure scheme is the effect of interfering physical effects that link the different physical nature of the variable to the main parameter, magnitude and transmission coefficients. It was found that the regular component of the error of the variable studied does not exceed 0.68%, and its random component does not exceed 1.28%. KEYWORDS Induction converter, large alternating current difference, symmetrical three-phase current, parametric structure circuit, magnetomodulation mode, transformer mode, error, additive error, multiplicative error. Volume 02 Issue 06-2022 59 American Journal Of Applied Science And Technology (ISSN – 2771-2745) VOLUME 02 ISSUE 06 Pages: 59-67 SJIF IMPACT FACTOR (2021: 5. 705) (2022: 5. 705) OCLC – 1121105677 METADATA IF – 5.582 Publisher: Oscar Publishing Services Servi

Доказательный фрагмент

«The article examines the large inductance difference passing through adjacent busbars and the new induction converter errors designed to measure the symmetry of three-phase currents using the parametric structure method.»

Образец извлечения

Демо-превью

The article examines the large inductance difference passing through adjacent busbars and the new induction converter errors designed to measure the symmetry of three-phase currents using the parametric structure method. Полный текст публикации CiteX не хранит — доступ к первоисточнику открывается по DOI согласно лицензии издателя и выбранному плану.

Цитирований
0
Тип
Журнал
Страна
Узбекистан
Ключевые слова
Induction converter, large alternating current difference, symmetrical three-phase current, parametric structure, autoimmune thyroiditis, thyroid nodules, tumors., FNAB, cytology, thyroid gland
Открыть DOI