К содержанию
РецензированоEN2026

The article examines the issues of discharge, treatment and quantity determination of waste water produced in industrial enterprises

Академические исследования в современной науке · 2026

Аннотация

The article examines the issues of discharge, treatment and quantity determination of waste water produced in industrial enterprises. The analysis of these indicators is considered in the case of Fergana city. KEYWORDS: industrial wastewater; cleaning methods; determine the amount of water. INTRODUCTION. Discharge and treatment of waste water generated in industrial enterprises, composition and properties of waste water, treatment of waste water, methods of treatment of retained waste and treatment of treated water, types of constructions used, their structure and methodology of their calculation, as well as the results of socio-economic reforms in our republic and regional problems issues of influence on the perspective of the wastewater treatment system are one of the most urgent issues of today. Rapid development of industrial enterprises is one of the factors of pollution of water bodies. While discharging large amounts of wastewater into water bodies, maintaining their purity is one of the important tasks in the municipal economy. Therefore, with the correct selection of industrial wastewater treatment methods, it is possible to ensure that the water discharged into water bodies fully complies with sanitary standards. The main part. In industrial enterprises, technical water is used in three directions: 1. From 70 to 89% of the incoming water for technical purposes is used in industrial enterprises as a refrigerant for cooling the products of heat exchange equipment, or to keep individual elements of devices and machines from overheating This water is heated by the product being cooled, but is not contaminated. 2. The amount of technical water from 5 to 12% is used for cleaning products or raw materials and as a transportation medium. This water becomes contaminated and heats up if the product is at a high temperature. 3. From 10 to 20% of technical water is lost due to evaporation or enters the composition of the manufactured product (steam, sugar, bread, etc.) 12 ACADEMIC RESEARCH IN MODERN SCIENCE International scientific-online conference Due to economic considerations, environmental requirements, as well as the limitation of water reserves in natural sources, it is recommended to install a circulation system of technical water supply in industrial enterprises. In the circulating system of technical water supply, water is used many times. According to the change in water quality during operation, circulating water supply is divided into the following: 1. "Clean cycles" - only for hot water when used; 2. "Dirty cycles" - when used only for polluted water; 3. "Mixed cycles" - when used, water is heated and polluted at the same time. Limit for technical water used in industrial enterprises of group 1the temperature is determined. T should be <30°С, its optimal value should be 15°С. In circulating water supply systems, carbonate hardness of water used as Sa and Mg cold carriers (chladonositel) should not exceed Jk- 2.8...3.0 mg-eq/l, and the possible concentration of its weight, according to the speed of water movement in cooling devices, is accepted. The technical water demand of the enterprise depends on the type of equipment used and the accepted scheme of the technological process. Qr is determined only according to the technical data of the water-consuming equipment. In the literature [10-12], information is provided on the limit norms of water consumption per unit of product (per unit of finished product weight). These data are obtained from the result of processing and determining the average amount of water consumption values (in one or another industry). But these standards do not fully take into account the peculiarities of each specific enterprise and can only be used for approximate calculations. It is considered appropriate to use the water used for the area of the water intake facility for circulating water supply. Recirculating schemes open up great opportunities in reducing the cost of the water supply system, reducing the consumption of fresh water and the discharge of dirty water. When creating circulation circuits, only 70-85% of technical water in technological equipment is used, after heating and cooling, the state of reuse. In these systems, it is possible to use some part of relatively less polluted technical water. Treated water (15%) is reused. In the circulation system of water supply, pumps deliver water to consumers through the water supply network. The heated and contaminated water from the consumers is directed to the wastewater treatment station through the pipeline system. Purified, but still 13 ACADEMIC RESEARCH IN MODERN SCIENCE International scientific-online conference warm, water is collected in a reservoir, from which it is transferred to a cooling unit with circulating water station pumps [4]. In it, the cooled water is again delivered to consumers by pumps. During the operation of the circulating system, part of the water is lost: it leaks, evaporates and flies a

Доказательный фрагмент

«The article examines the issues of discharge, treatment and quantity determination of waste water produced in industrial enterprises.»

Образец извлечения

Демо-превью

The article examines the issues of discharge, treatment and quantity determination of waste water produced in industrial enterprises. Полный текст публикации CiteX не хранит — доступ к первоисточнику открывается по DOI согласно лицензии издателя и выбранному плану.

Цитирований
0
Просмотров
0
Тип
Журнал
Страна
Узбекистан
Ключевые слова
industrial wastewater, cleaning methods, determine the, personal pronouns, reported speech, possessives, direct speech, indirect speech, syntactic units, use of conjunctions., personal pronoun changes, verb tense adaptation, author’s words