Orthopedic Treatment When Using Non-Metal Ceramic Prosthesis YAKUBOVA Sarvinoz Rakhmonkulovna
PAGE NO. - · YAKUBOVA Sarvinoz Rakhmonkulovna
American Journal Of Social Sciences And Humanity Research · 05 · 2025
Аннотация
Objective: To determine the changes that occur in periodontal tissues, prosthetic bed and oral mucosa before and after orthopedic treatment when using metal-free ceramic prostheses. Methods: During the study, general clinical, laboratory, biochemical, functional, instrumental and statistical methods were used. The object of the study was 185 patients with partial edentia aged 25-60 years were selected, 95 of whom were men and 90 were women, and the control group consisted of 20 healthy people. Results: The wear of non-removable prostheses during wearing is manifested in the following pathological changes in the condition of the prostheses and the tissues of the prosthetic bed. Stamped and stamped welded prostheses with and without ZDP TT have a number of technological shortcomings, which are manifested during wearing. Conclusions: Dentures lead to a change in the acid-base balance of oral fluid, complete cast dentures without a protective and decorative coating have the least effect on it ((pH 7.2±0.03, from 12 months after denture insertion to the end of the study), metal-ceramic dentures have a small effect (pH 7.39±0.02 from 12 months after denture insertion to the end of the study). Keywords: Orthopedic, prosthetic construction, ceramics, non-removable dentures, oral cavity. partial edentia aged 25-60 years, 95 of whom were Introduction: Wide-scale measures are being men and 90 were women, the control group consisted implemented in our country to develop the system of of 20 healthy people. the medical field, in particular, to reduce dental diseases and their complications, as well as to provide The results of the study: wear of non-removable qualified medical care to patients suffering from this dentures during wearing is manifested in the pathology, and the following tasks have been defined. deterioration of the condition of the dentures and the "...in order to increase the quality and convenience of following pathological changes in the tissues of the the effectiveness of medical care, it is necessary to denture base. Stamped and stamped welded dentures introduce high-tech methods for the implementation with and without ZDP TT have a number of of a healthy lifestyle and prevention of diseases, as well technological shortcomings that manifest themselves as diagnosis and treatment, standardization methods during wearing. in medicine, and the implementation of the In addition, the development of the electrochemical- effectiveness of patronage and dispensary models..." mechanical corrosion process of the metal prosthesis The purpose of the study: to determine the changes leads to a change in the color and gloss of the above- that occur in periodontal tissues, prosthetic bed and mentioned areas, which turns into extensive flatness oral mucosa before and after orthopedic treatment defects that penetrate deep into the prosthesis. The when using metal-free ceramic prostheses. sufficient service life of stamped and, especially, stamped welded dentures is limited by the variety of The object of the study was selected 185 patients with materials in their composition, which leads to its American Journal Of Social Sciences And Humanity Research 154 https://theusajournals.com/index.php/ajsshr American Journal Of Social Sciences And Humanity Research (ISSN: 2771-2141) perforation. Often, perforation is localized on the color and gloss of the coating surface of the TQDP did occlusal surface of a crushed artificial coating - it is not change, but at the end of the study, the change in under the strong influence of all possible destructive the marginal color and gloss occurred in 34.3% of cases. factors - the mechanical effect of chewed food, the The study found that in patients in the TQDP group, the aggressive chemical effect of oral fluid, and color and gloss of the coating surface changed due to electrochemical processes. corrosion, which increases friction of the prosthesis surface with the ZDP TT the effect of the first two factors on the alloy. surface and mechanical abrasion of the coating, while ZDT TT contributes significantly to the deterioration of in the cast and cast-fused prosthesis group, the the operational characteristics of cast and cast welded destruction process of the metal prosthetic material structures, which leads to the weakening of the above- began. The non-change in the color and gloss of the TQ mentioned alloy structure due to the thermal process prostheses in the highly aggressive environment of the of the alloy or the alloy. The technologically necessary oral cavity indicates their high chemical and mechanical temperature for the application of ZDP TT is the stability. On the other hand, the high percentage of material, which is heated to 600-800 degrees, followed prosthesis destruction of the ZDP TT prostheses by slow cooling of the prosthesis. indicates their lack of durability. In patients with TQ and CLDP prostheses, the appearance of gaps, holes or Prolonged cooling by local exposure
Доказательный фрагмент
«Objective: To determine the changes that occur in periodontal tissues, prosthetic bed and oral mucosa before and after orthopedic treatment when using metal-free ceramic prostheses.»
Образец извлечения
Демо-превьюObjective: To determine the changes that occur in periodontal tissues, prosthetic bed and oral mucosa before and after orthopedic treatment when using metal-free ceramic prostheses. Полный текст публикации CiteX не хранит — доступ к первоисточнику открывается по DOI согласно лицензии издателя и выбранному плану.
- Цитирований
- 0
- Тип
- Журнал
- Страна
- Узбекистан
- Ключевые слова
- Orthopedic, prosthetic construction, ceramics, non-removable dentures, oral cavity